- Additives
- Instruments
- Appearance
- Color
- Physical Properties
- Abrasion
- Adhesion
- Application
- byko-charts
- Opacity Drawdown Charts
- Penopac Charts / Opacity Measurement
- Display-, Checkerboard-, Spreading Rate Charts
- Brushout / Plain White Cards
- Uncoated Test Charts, Drawdown Plate
- Sag and Leveling Test Charts, Spray Monitors, Inter-leaf Paper
- Clear Polyester Film, Scrub Test Panels
- High quality drawdown bar film applicators with calibration certificates
- 4-Sided Applicator / Applicator Frame
- Bar Type / U Shaped
- Multiple Clearance Square Applicator
- BYK-Gardner Film Casting Knife
- Wire-wound rods
- Step Gap Film Applicator
- Dow Latex Film Applicator
- Leveling/Sagging Tester
- NYPC Leveling Test Blade
- Anti-Sag Meter
- Pfund Cryptometer
- Vacuum Pump
- Vacuum Plates
- Automatic Film Applicators
- byko-drive
- Balances
- Conductivity
- Density
- Dispersion
- Fineness of Grind Gages - Hegman Gages
- Dispermat® High Speed Dissolvers
- Dispermat® CN High Speed Dissolvers
- Dispermat® CA High Speed Dissolvers
- Dispermat® AE High Shear Mixers and Dispersers
- Dispermat® Air Pressure Systems (APS) for High Speed Dissolvers
- SystemDispermat® TML Basket Milling System
- Dispermat® Disperser CDS Vacuum Dissolver Attachment
- Dispermat® VL® Disperser High Speed Vacuum Dissolvers
- WIN-DISP® Software Program for C-Type Dispermats®
- Safety Device / Stainless Steel Covers
- Stainless Steel Containers
- Light-Weight Dispersion Impellers
- Heavy-Duty Dispersion Impellers
- Propeller Blades
- Media Mill Impellers for Using Dissolvers as Vertical Bead Mills
- Disperser Homogenizer
- Dispermat® SL-M disperser with constant speed control
- Dispermat® SL-C with constant speed and constant mechanical power control
- Dispermat® AS Rotor-Stator Dispersion System
- “Quickee” Ball Mill
- Drying Time
- Permeability Cups
- Film Thickness
- Wet Film Thickness Gages
- Interchemical Thickness Gages
- byko-test 4500/4200 dry film thickness gages
- byko-test 8500 dry film thickness gage
- byko-test MP0R dry film thickness gage
- micro-TRI-gloss µ glossmeter film gauge
- Certified Precision Plastic Shims
- byko-cut universal
- Destructive Film Thickness Measurement
- Buchholz Hardness Test
- Multi-Cut Tools for Cross-Cut Test
- PosiTector 6000 film gauge – Basic Models
- PosiTector 6000 film gauge – Standard Models
- PosiTector 6000 film gauge – Memory Models
- PosiTector 6000 Probe Details
- Hardness
- Impact / Flexibility
- Microscopes
- Temperature
- Viscosity
- Bubble Viscometers
- Bubble Viscometer Tubes
- Viscosity Cups
- DIN/ISO Dip Cup
- Zahn-Type Dip Cups
- S90 Signature and EZ Series Zahn Cups
- Flow Cups
- Rotational Viscometers
- DV-E Rotational Viscometer
- UL Adapter
- Helipath Stand
- Digital KU-2 Stormer-Type Viscometer
- CAP 1000+ / CAP 2000+
- CAPCALC 32 Software
- Standard Oils for Zahn and Ford Flow Cups
- Standard Oils for Rotational Viscometers
- Standard Oils for KU-Series Stormer-Type Viscometers
- Standard Oils for CAP Viscometers
- Standard Oils for Analog Cone and Plate Viscometers
- Publications / Books
- Shop
- Promotions
- Support
- Press & Events
- Innovation
- Company
- Contact Us
- back
- closeopen
- enlargereduce
LCM III
The LCM III is a reliable color instrument which replaces conventional visual color evaluation with an objective measurement. It is ideal for routine production control of clear, transparent liquids like resins, adhesives and solvents.
- Large touch-screen display with intuitive user guidance for simple operation
- Automatic cuvette recognition - avoids faulty data measurement
- Works with 10 and 50 mm rectangle as well as 11 mm round cuvettes for optimum precision
- Gardner, Hazen (APHA/PtCo), Iodine, Saybolt and Mineral oil scales come standard with instrument
- Reference beam design to maximize the accuracy and precision
- Truly portable with the use of an optional lithium-ion battery
- USB interface for PC or printer connection
Comes complete with:
Instrument with dust cover
External power supply
Adapter for 10 mm rectangle cuvettes
addista® – color standards
Disposable plastic cuvettes (10x50 mm) - pack of 10
Disposable glass cuvettes (11mm) - pack of 10
Operating manual
¹ Based on data with 11 mm cuvette
² Based on data with 50 mm cuvette
³ Based on data with 50 mm cuvette for Hazen and 11 mm cuvette for
Iodine and Gardner
| Ordering Information | Technical Specifications |
| Cat. No. | Description | Price | Voltage | |||
| CL-9552 | LCM III | 100 - 240 V, 50 / 60 Hz | ||||
| Standards |
| ASTM | D 156, D 1045, D 1209, D 1544, D 1500 | |
| DIN | 6162 | |
| ISO | 4630, 6271, 2049 | |
| Type | Single-beam photometer with reference beam path | |
| Spectral Range | 400 to 700 nm, 20 nm resolution | |
| Repeatability | ± 2 Hazen¹, ± 0.1 Gardner² | |
| Reproducibility³ | ± 0.3 Iodine, ± 5 Hazen, ± 0.3 Gardner | |
| Light Source | Tungsten Halogen Lamp | |
| Indices | Hazen / APHA (0 to 1000), Gardner (0 to 18), Iodine (0 to 120), Saybolt (-16 to 30), Mineral Oil (ASTM D 1500) 0 to 8 | |
| Memory | 200 color measurements | |
| Data Export | *.csv file to USB flash drive or optional DataTrans Software | |
| Interface | USB-A for printer and USB memory stick USB-B for communication with PC |
|
| Operating Temperature | 10 - 40 °C (50 - 104 °F) | |
| Humidity | up to 80%, 35 °C (95 °F); non condensing | |
| Dimensions | 220 x 135 x 330 mm (8.6 x 5.3 x 12.9 in.) | |
| Weight | 4.1 kg (9.0 lbs) | |







