- Additives
- Instruments
- Appearance
- Color
- Physical Properties
- Abrasion
- Adhesion
- Application
- byko-charts
- Opacity Drawdown Charts
- Penopac Charts / Opacity Measurement
- Display-, Checkerboard-, Spreading Rate Charts
- Brushout / Plain White Cards
- Uncoated Test Charts, Drawdown Plate
- Sag and Leveling Test Charts, Spray Monitors, Inter-leaf Paper
- Clear Polyester Film, Scrub Test Panels
- High quality drawdown bar film applicators with calibration certificates
- 4-Sided Applicator / Applicator Frame
- Bar Type / U Shaped
- Multiple Clearance Square Applicator
- BYK-Gardner Film Casting Knife
- Wire-wound rods
- Step Gap Film Applicator
- Dow Latex Film Applicator
- Leveling/Sagging Tester
- NYPC Leveling Test Blade
- Anti-Sag Meter
- Pfund Cryptometer
- Vacuum Pump
- Vacuum Plates
- Automatic Film Applicators
- byko-drive
- Balances
- Conductivity
- Density
- Dispersion
- Fineness of Grind Gages - Hegman Gages
- Dispermat® High Speed Dissolvers
- Dispermat® CN High Speed Dissolvers
- Dispermat® CA High Speed Dissolvers
- Dispermat® AE High Shear Mixers and Dispersers
- Dispermat® Air Pressure Systems (APS) for High Speed Dissolvers
- SystemDispermat® TML Basket Milling System
- Dispermat® Disperser CDS Vacuum Dissolver Attachment
- Dispermat® VL® Disperser High Speed Vacuum Dissolvers
- WIN-DISP® Software Program for C-Type Dispermats®
- Safety Device / Stainless Steel Covers
- Stainless Steel Containers
- Light-Weight Dispersion Impellers
- Heavy-Duty Dispersion Impellers
- Propeller Blades
- Media Mill Impellers for Using Dissolvers as Vertical Bead Mills
- Disperser Homogenizer
- Dispermat® SL-M disperser with constant speed control
- Dispermat® SL-C with constant speed and constant mechanical power control
- Dispermat® AS Rotor-Stator Dispersion System
- “Quickee” Ball Mill
- Drying Time
- Permeability Cups
- Film Thickness
- Wet Film Thickness Gages
- Interchemical Thickness Gages
- byko-test 4500/4200 dry film thickness gages
- byko-test 8500 dry film thickness gage
- byko-test MP0R dry film thickness gage
- micro-TRI-gloss µ glossmeter film gauge
- Certified Precision Plastic Shims
- byko-cut universal
- Destructive Film Thickness Measurement
- Buchholz Hardness Test
- Multi-Cut Tools for Cross-Cut Test
- PosiTector 6000 film gauge – Basic Models
- PosiTector 6000 film gauge – Standard Models
- PosiTector 6000 film gauge – Memory Models
- PosiTector 6000 Probe Details
- Hardness
- Impact / Flexibility
- Microscopes
- Temperature
- Viscosity
- Bubble Viscometers
- Bubble Viscometer Tubes
- Viscosity Cups
- DIN/ISO Dip Cup
- Zahn-Type Dip Cups
- S90 Signature and EZ Series Zahn Cups
- Flow Cups
- Rotational Viscometers
- DV-E Rotational Viscometer
- UL Adapter
- Helipath Stand
- Digital KU-2 Stormer-Type Viscometer
- CAP 1000+ / CAP 2000+
- CAPCALC 32 Software
- Standard Oils for Zahn and Ford Flow Cups
- Standard Oils for Rotational Viscometers
- Standard Oils for KU-Series Stormer-Type Viscometers
- Standard Oils for CAP Viscometers
- Standard Oils for Analog Cone and Plate Viscometers
- Publications / Books
- Shop
- Promotions
- Support
- Press & Events
- Innovation
- Company
- Contact Us
- back
- closeopen
- enlargereduce
LCS III
The LCS III is a highly precise color instrument which spectrally measures all color shades of optically clear liquids. Besides the conventional visual color numbers (Gardner, Iodine, Hazen (APHA) etc.) the LCS can measure opponent color such as CIELab, XYZ and Yxy under the conditions of illuminant C (daylight) and 2° Standard Observer.
- Stand alone unit with built-in touch-screen display allows use without the need of a PC
- Automatic cuvette detection - avoids faulty data measurement
- Designed for the use of disposable plastic cuvettes, high precision optical glass cuvettes or 11 mm test tubes
- Automatic zero and calibration memory for all type of cuvettes - ensures use of correct calibration data
- All important color scales and indices included
- Highly accurate and reliable results are ensured by the dual beam principle
- User profile memory with password protection for individual configurations - including GLP documentation
- Open sample compartment for ease of operation
- USB interface for PC or printer connection
Comes complete with:
Instrument with dust cover
External power supply
Adapter for 10 mm rectangle cuvettes
addista® – color standards
Disposable plastic cuvettes (10x50 mm) - pack of 10
Disposable glass cuvettes (11mm) - pack of 10
Operating manual
¹ Referred to distilled water
| Ordering Information | Technical Specifications |
| Cat. No. | Description | Price | Voltage | |||
| CL-9572 | LCS III | 100-240 V / 50 / 60 Hz | ||||
| Standards |
| AOCS | Method Cc 13e | |
| ASTM | D 156, D 1045, D 1209, D 1544, D 1925, D 1500 | |
| DIN | 6162 | |
| ISO | 4630, 6271, 2049 | |
| Geometry | 0° / 180° rectilinear | |
| Spectral Range (Colorimetric) | 380 to 720 nm, 10 nm resolution | |
| Spectral Range (Photometric) | 320 to 1,100 nm, 1 nm resolution | |
| Repeatability | 0.1 ΔE*, 1 ơ | |
| Reproducibility¹ | ± 0.2% transmission | |
| Light Source | Tungsten Halogen Lamp | |
| Illuminant/Observer | C/2° | |
| Color Scale | CIELab; CIELCH; XYZ; Yxy; Lab (h) | |
| Color Difference | ΔE* and component differences, text descriptor, tolerances | |
| Indices | Gardner, Hazen/APHA, Iodine, Saybolt, Lovibond, Hess-Ives, European and US Pharmacopoeia, Klett, Mineral oil, Yellowness ASTM D 1925, ADMI, Chlorophyll A | |
| Spectral | % transmission; % absorbance, concentration | |
| Memory | 500 color measurements, 50 color references, 500 photometric readings | |
| Data Export | *.csv file to USB memory stick or optional DataTrans software | |
| Interface | USB-A for printer and USB memory stick USB-B for communication with a PC |
|
| Operating Temperature | 10 to 40 °C (50 to 104 °F) | |
| Humidity | up to 85%, 35 °C (95 °F);non condensing | |
| Dimensions | 368 x 144 x 359 mm (14.5 x 5.7 x 14.1 in) | |
| Weight | 6.4 kg (14.1 lbs) | |







