- Additives
- Instruments
- Appearance
- Color
- Physical Properties
- Abrasion
- Adhesion
- Application
- byko-charts
- Opacity Drawdown Charts
- Penopac Charts / Opacity Measurement
- Display-, Checkerboard-, Spreading Rate Charts
- Brushout / Plain White Cards
- Uncoated Test Charts, Drawdown Plate
- Sag and Leveling Test Charts, Spray Monitors, Inter-leaf Paper
- Clear Polyester Film, Scrub Test Panels
- High quality drawdown bar film applicators with calibration certificates
- 4-Sided Applicator / Applicator Frame
- Bar Type / U Shaped
- Multiple Clearance Square Applicator
- BYK-Gardner Film Casting Knife
- Wire-wound rods
- Step Gap Film Applicator
- Dow Latex Film Applicator
- Leveling/Sagging Tester
- NYPC Leveling Test Blade
- Anti-Sag Meter
- Pfund Cryptometer
- Vacuum Pump
- Vacuum Plates
- Automatic Film Applicators
- byko-drive
- Balances
- Conductivity
- Density
- Dispersion
- Fineness of Grind Gages - Hegman Gages
- Dispermat® High Speed Dissolvers
- Dispermat® CN High Speed Dissolvers
- Dispermat® CA High Speed Dissolvers
- Dispermat® AE High Shear Mixers and Dispersers
- Dispermat® Air Pressure Systems (APS) for High Speed Dissolvers
- SystemDispermat® TML Basket Milling System
- Dispermat® Disperser CDS Vacuum Dissolver Attachment
- Dispermat® VL® Disperser High Speed Vacuum Dissolvers
- WIN-DISP® Software Program for C-Type Dispermats®
- Safety Device / Stainless Steel Covers
- Stainless Steel Containers
- Light-Weight Dispersion Impellers
- Heavy-Duty Dispersion Impellers
- Propeller Blades
- Media Mill Impellers for Using Dissolvers as Vertical Bead Mills
- Disperser Homogenizer
- Dispermat® SL-M disperser with constant speed control
- Dispermat® SL-C with constant speed and constant mechanical power control
- Dispermat® AS Rotor-Stator Dispersion System
- “Quickee” Ball Mill
- Drying Time
- Permeability Cups
- Film Thickness
- Wet Film Thickness Gages
- Interchemical Thickness Gages
- byko-test 4500/4200 dry film thickness gages
- byko-test 8500 dry film thickness gage
- byko-test MP0R dry film thickness gage
- micro-TRI-gloss µ glossmeter film gauge
- Certified Precision Plastic Shims
- byko-cut universal
- Destructive Film Thickness Measurement
- Buchholz Hardness Test
- Multi-Cut Tools for Cross-Cut Test
- PosiTector 6000 film gauge – Basic Models
- PosiTector 6000 film gauge – Standard Models
- PosiTector 6000 film gauge – Memory Models
- PosiTector 6000 Probe Details
- Hardness
- Impact / Flexibility
- Microscopes
- Temperature
- Viscosity
- Bubble Viscometers
- Bubble Viscometer Tubes
- Viscosity Cups
- DIN/ISO Dip Cup
- Zahn-Type Dip Cups
- S90 Signature and EZ Series Zahn Cups
- Flow Cups
- Rotational Viscometers
- DV-E Rotational Viscometer
- UL Adapter
- Helipath Stand
- Digital KU-2 Stormer-Type Viscometer
- CAP 1000+ / CAP 2000+
- CAPCALC 32 Software
- Standard Oils for Zahn and Ford Flow Cups
- Standard Oils for Rotational Viscometers
- Standard Oils for KU-Series Stormer-Type Viscometers
- Standard Oils for CAP Viscometers
- Standard Oils for Analog Cone and Plate Viscometers
- Publications / Books
- Shop
- Promotions
- Support
- Press & Events
- Innovation
- Company
- Contact Us
- back
- closeopen
- enlargereduce
BYK-Gardner offers two levels of color control software for recording, analyzing and documenting color measurement results in the laboratory and production.
- auto-QC lite for basic QC requirements
- auto-QC with advanced features
- auto-QC lite automatically calculates tolerances based on measured production trials. Asymmetrical fit allows best agreement with the visual perception
- Tolerances defined by the customer can be manually input in any color scale
- Metamerism is no longer a problem – display results of up to 3 illuminants on one screen
auto-QC
Color Control Software
auto-QC lite offers the following
capabilities:
-
Customized screen layouts for ease of operation
-
Pass/Fail, color-on-screen and text description let the user see in a flash whether he is on target or not
- SPC control charts with upper/lower control limits for any index and color scale allow the user to recognize trial color deviations over time and trends early
color-view
- Direct transfer of all colorimetric data, spectral data and indices into Excel® can be easily accomplished
auto-QC
Supports the BYK-Gardner color instruments color-view and spectro-guide – and other commonly available spectrophotometers.
spectro-guide family
In addition, auto-QC offers the
following advanced features:
-
Easy creation of macros:
Different software steps are combined into one procedure. One keystroke executes the macro and guides inexperienced users through their measurement tasks -
Direct transfer of data into a database like Microsoft Access® allows production batches to be archived and recalled for future comparison
- Use the direct e-mail tools to transfer color data worldwide in a second
- Easy to use with customized screen layouts
- Pass/Fail analysis with auto-tolerancing
- Export of color data to Excel® wihtin a second
Comes complete with:
Software on CD-ROM
Protection key for USB port
All instrument drivers
Hardware Requirements:
Operating system: Windows 2000 or higher
Memory: min. 8 MB RAM (recommended 64 MB)
Hard disk capacity: min. 5 MB
Monitor resolution: VGA or better
Disk drive: CD-ROM
Interface: serial interface and USB port
Color Control Software
Note: If using a PC with USB port and the spectrophotometer spectro-guide, please order the special USB-adapter CC-6813.
| Ordering Information |
| Cat. No. | Description | Price | ||
| CS-6531 | BYKWARE auto-QC | |||
| CS-6532 | BYKWARE auto-QC lite | |||
| Technical Specifications |
| Illuminants | A; C; D50; D55; D65; D75; F2; F6; F7; F8; F10; F11; UL30; UL50 | |
| Scales | CIELab; CIELCH; L,a,b (Hunter); CIELuv; XYZ; Yxy; RxRyRz | |
| Differences | ΔE*; ΔE(h); ΔECMC; ΔE94; ΔEFMC2; ΔE99; ΔE2000 | |
| Spectral Data | %R; %T; K/S; ln K/S; -ln K/S; Absorbance; ln Absorbance | |
| Indices | Metamerism: CIE, DIN Yellowness: ASTM D 1925; E 313; DIN 6167 Whiteness: CIE; ASTM E 313; Berger; Hunter; Stensby; Taube Munsell: Hue/Value/Chroma Opacity Color Strength Gloss: color-view and spectro-guide only |
|
| Observer | 2°; 10° | |
| Languages | English, German, French, Italian, Spanish, Japanese, Chinese | |