- Additives
- Instruments
- Appearance
- Color
- Physical Properties
- Abrasion
- Adhesion
- Application
- byko-charts
- Opacity Drawdown Charts
- Penopac Charts / Opacity Measurement
- Display-, Checkerboard-, Spreading Rate Charts
- Brushout / Plain White Cards
- Uncoated Test Charts, Drawdown Plate
- Sag and Leveling Test Charts, Spray Monitors, Inter-leaf Paper
- Clear Polyester Film, Scrub Test Panels
- High quality drawdown bar film applicators with calibration certificates
- 4-Sided Applicator / Applicator Frame
- Bar Type / U Shaped
- Multiple Clearance Square Applicator
- BYK-Gardner Film Casting Knife
- Wire-wound rods
- Step Gap Film Applicator
- Dow Latex Film Applicator
- Leveling/Sagging Tester
- NYPC Leveling Test Blade
- Anti-Sag Meter
- Pfund Cryptometer
- Vacuum Pump
- Vacuum Plates
- Automatic Film Applicators
- byko-drive
- Balances
- Conductivity
- Density
- Dispersion
- Fineness of Grind Gages - Hegman Gages
- Dispermat® High Speed Dissolvers
- Dispermat® CN High Speed Dissolvers
- Dispermat® CA High Speed Dissolvers
- Dispermat® AE High Shear Mixers and Dispersers
- Dispermat® Air Pressure Systems (APS) for High Speed Dissolvers
- SystemDispermat® TML Basket Milling System
- Dispermat® Disperser CDS Vacuum Dissolver Attachment
- Dispermat® VL® Disperser High Speed Vacuum Dissolvers
- WIN-DISP® Software Program for C-Type Dispermats®
- Safety Device / Stainless Steel Covers
- Stainless Steel Containers
- Light-Weight Dispersion Impellers
- Heavy-Duty Dispersion Impellers
- Propeller Blades
- Media Mill Impellers for Using Dissolvers as Vertical Bead Mills
- Disperser Homogenizer
- Dispermat® SL-M disperser with constant speed control
- Dispermat® SL-C with constant speed and constant mechanical power control
- Dispermat® AS Rotor-Stator Dispersion System
- “Quickee” Ball Mill
- Drying Time
- Permeability Cups
- Film Thickness
- Wet Film Thickness Gages
- Interchemical Thickness Gages
- byko-test 4500/4200 dry film thickness gages
- byko-test 8500 dry film thickness gage
- byko-test MP0R dry film thickness gage
- micro-TRI-gloss µ glossmeter film gauge
- Certified Precision Plastic Shims
- byko-cut universal
- Destructive Film Thickness Measurement
- Buchholz Hardness Test
- Multi-Cut Tools for Cross-Cut Test
- PosiTector 6000 film gauge – Basic Models
- PosiTector 6000 film gauge – Standard Models
- PosiTector 6000 film gauge – Memory Models
- PosiTector 6000 Probe Details
- Hardness
- Impact / Flexibility
- Microscopes
- Temperature
- Viscosity
- Bubble Viscometers
- Bubble Viscometer Tubes
- Viscosity Cups
- DIN/ISO Dip Cup
- Zahn-Type Dip Cups
- S90 Signature and EZ Series Zahn Cups
- Flow Cups
- Rotational Viscometers
- DV-E Rotational Viscometer
- UL Adapter
- Helipath Stand
- Digital KU-2 Stormer-Type Viscometer
- CAP 1000+ / CAP 2000+
- CAPCALC 32 Software
- Standard Oils for Zahn and Ford Flow Cups
- Standard Oils for Rotational Viscometers
- Standard Oils for KU-Series Stormer-Type Viscometers
- Standard Oils for CAP Viscometers
- Standard Oils for Analog Cone and Plate Viscometers
- Publications / Books
- Shop
- Promotions
- Support
- Press & Events
- Innovation
- Company
- Contact Us
- back
- closeopen
- enlargereduce
BYK LC 2
Conductivity Meter
Provides measurement of electrical conductivity of solvents and solvent borne paint formulations for electrostatic spray applications.
- Stainless steel measuring cell and electrodes
- Solvent resistant housing
When measuring conductivity, liquid builds up a specific ohmic resistance to the electric current, depending on the applied voltage. The reciprocal value is the conductivity. The measured resistance depends on the geometric arrangement of the electrodes within the measuring cell. In order to be independent of the measuring cell, the measured resistance has to be divided by the cell constant "C" which yields specific resistance. The specific resistance describes the application and performance properties of electrocoating paints.
The BYK-Gardner LC 2 Conductivity Meter was developed in cooperation with the VDA (Association of German Automotive Industry) following VDA standards.
Measurement of the resistance of liquid paints is carried out in the annular passage of the measuring cell. The measuring cell consists of two separable parts. The electrodes are arranged concentrically (Cat. No. PW-1710) or parallel (Cat. No. PW-1712), thus forming an annular passage. They are insulated from each other.
The electrodes of the measuring cell are made of stainless steel, with the surface polished and therefore easy to clean. Only an absolutely clean measuring cell guarantees that the entire surface of the electrode is available for measurement. The probe is impervious and can be immersed in solvents for a short time.
This conductivity meter works only with solvents and solvent based paints. The presence of water will cause electrolysis and results in false readings.
Use the BYK LC-3 or BYK LC-4 for waterborne systems
Note: BYK LC 2 Meter and measuring cell must be ordered separately. Also please order PW-1713 space holders when ordering the PW-1712 measuring cell
Conductivity Meter
Measuring Cell
Very easy to clean - Measuring Cell
For Preventive Maintenance see page 272.
| Ordering Information | Technical Specifications |
| Standards |
| ASTM | D 5682 | |
| DIN | 55667 | |







