Digital KU-2
Stormer Type Viscometer
The digital KU-2 viscometer provides a direct digital reading in Krebs units (KU), centipoise, and grams (gm). This simplifies an established test procedure providing an immediate calculation of the viscosity value. The viscometer automatically starts or stops by lowering or raising the viscometer. The KU-2 automatically establishes the correct rotational speed to comply with ASTM method D 562.
- Easy to use – no weights or stroboscopic timing attachment
- Switch selectable LED digital display of Krebs units or grams or centipoise
- Allows for rapid and easy measurement of samples
- Parallel printer output for test documentation
- Instrument base fits standard pint, 1/2 pint and quart cans
- Traceable to NIST
The Digital KU-2 can be equipped with an air purge that allows the interior of the instrument to be pressurized with air or inert gas. Recommended when working in a hazardous environment.
*Centipoise values are based on the conversion from Krebs Units as defined in the ASTM standard D562
Comes complete with:
Digital KU-2
1 spindle (paddle type)
Adapters for 1 pint, 1/2 pint
Operation Manual
For Rotational Oils see page 262.
| |
|
| Ordering Information | |
Technical Specifications |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
| | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
| PV-7508 |
|
KU-2, 115V |
|
 | | 40-141 KU; 32-1090 grams; 27-5274 cP* | | 0.1 KU; 1.0 gm; 0.7 cP | | within ± 1 %
full scale | | within ± 0.5 %
full scale | | 115V/60Hz | | 200 rpm ±0.1 rpm |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
| PV-7509 |
|
KU-2, 230V |
|
 | | 40-141 KU; 32-1090 grams; 27-5274 cP* | | 0.1 KU; 1.0 gm; 0.7 cP | | within ± 1% full scale | | within ± 0.5% full scale | | 230V/50Hz | | 200 rpm ±0.1 rpm |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
| PV-8322 |
|
KU-2 with air purge, 115V |
|
 | | 40-141 KU; 32-1090 grams; 27-5274 cP* | | 0.1 KU; 1.0 gm; 0.7 cP | | within ± 1 %
full scale | | within ± 0.5 %
full scale | | 115V/60Hz | | 200 rpm ± 0.1 rpm |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
| PV-8323 |
|
KU-2 with air purge, 230V |
|
 | | 40-141 KU; 32-1090 grams; 27-5274 cP* | | 0.1 KU, 1.0 gm; 0.7 cP | | within ±1% full scale | | within ± 0.5% full scale | | 230V/50Hz | | 200 rpm ±0.1 rpm |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
|
|
|
|
| | | | | | | | | | | | |
| |
|
| Ordering Information | |
Accessories |
|
|
|
|
| | |
|
|
|
|
| | |
|
|
|
|
| | |
|
|
|
|
|
|
|
| | |
|
|
|
|
| | |
|
|
|
|
| | |
| PV-7510 |
|
KU-2 Spindle |
|
 | | Replacement for Digital KU-2 Stormer-Type Viscometer |
|
|
|
|
| | |
|
|
|
|
| | |
|
|
|
|
| | |
| PV-7511 |
|
KU-2 Paste Spindle |
|
 | | non-reference spindle for relative measurements of pastes |
|
|
|
|
| | |
|
|
|
|
| | |
|
|
|
|
| | |
|
10 - 40 °C |
| | |
| | |
| | |
|
20 x 11 x 15 in |
| | |
| | |
| | |
|
10 kg (20 lbs) |
| | |
| | |
| | |