- Additives
- Instruments
- Appearance
- Color
- Physical Properties
- Abrasion
- Adhesion
- Application
- byko-charts
- Opacity Drawdown Charts
- Penopac Charts / Opacity Measurement
- Display-, Checkerboard-, Spreading Rate Charts
- Brushout / Plain White Cards
- Uncoated Test Charts, Drawdown Plate
- Sag and Leveling Test Charts, Spray Monitors, Inter-leaf Paper
- Clear Polyester Film, Scrub Test Panels
- High quality drawdown bar film applicators with calibration certificates
- 4-Sided Applicator / Applicator Frame
- Bar Type / U Shaped
- Multiple Clearance Square Applicator
- BYK-Gardner Film Casting Knife
- Wire-wound rods
- Step Gap Film Applicator
- Dow Latex Film Applicator
- Leveling/Sagging Tester
- NYPC Leveling Test Blade
- Anti-Sag Meter
- Pfund Cryptometer
- Vacuum Pump
- Vacuum Plates
- Automatic Film Applicators
- byko-drive
- Balances
- Conductivity
- Density
- Dispersion
- Fineness of Grind Gages - Hegman Gages
- Dispermat® High Speed Dissolvers
- Dispermat® CN High Speed Dissolvers
- Dispermat® CA High Speed Dissolvers
- Dispermat® AE High Shear Mixers and Dispersers
- Dispermat® Air Pressure Systems (APS) for High Speed Dissolvers
- SystemDispermat® TML Basket Milling System
- Dispermat® Disperser CDS Vacuum Dissolver Attachment
- Dispermat® VL® Disperser High Speed Vacuum Dissolvers
- WIN-DISP® Software Program for C-Type Dispermats®
- Safety Device / Stainless Steel Covers
- Stainless Steel Containers
- Light-Weight Dispersion Impellers
- Heavy-Duty Dispersion Impellers
- Propeller Blades
- Media Mill Impellers for Using Dissolvers as Vertical Bead Mills
- Disperser Homogenizer
- Dispermat® SL-M disperser with constant speed control
- Dispermat® SL-C with constant speed and constant mechanical power control
- Dispermat® AS Rotor-Stator Dispersion System
- “Quickee” Ball Mill
- Drying Time
- Permeability Cups
- Film Thickness
- Wet Film Thickness Gages
- Interchemical Thickness Gages
- byko-test 4500/4200 dry film thickness gages
- byko-test 8500 dry film thickness gage
- byko-test MP0R dry film thickness gage
- micro-TRI-gloss µ glossmeter film gauge
- Certified Precision Plastic Shims
- byko-cut universal
- Destructive Film Thickness Measurement
- Buchholz Hardness Test
- Multi-Cut Tools for Cross-Cut Test
- PosiTector 6000 film gauge – Basic Models
- PosiTector 6000 film gauge – Standard Models
- PosiTector 6000 film gauge – Memory Models
- PosiTector 6000 Probe Details
- Hardness
- Impact / Flexibility
- Microscopes
- Temperature
- Viscosity
- Bubble Viscometers
- Bubble Viscometer Tubes
- Viscosity Cups
- DIN/ISO Dip Cup
- Zahn-Type Dip Cups
- S90 Signature and EZ Series Zahn Cups
- Flow Cups
- Rotational Viscometers
- DV-E Rotational Viscometer
- UL Adapter
- Helipath Stand
- Digital KU-2 Stormer-Type Viscometer
- CAP 1000+ / CAP 2000+
- CAPCALC 32 Software
- Standard Oils for Zahn and Ford Flow Cups
- Standard Oils for Rotational Viscometers
- Standard Oils for KU-Series Stormer-Type Viscometers
- Standard Oils for CAP Viscometers
- Standard Oils for Analog Cone and Plate Viscometers
- Publications / Books
- Shop
- Promotions
- Support
- Press & Events
- Innovation
- Company
- Contact Us
- back
- closeopen
- enlargereduce
Flow Cups
Ford Viscosity Cups
BYK-Gardner Ford Viscosity Cups are guaranteed to be within 3% (drain time of calibration oil) throughout the recommended use range.
- For low viscosity liquids
- Body made of solid bar aluminum
- Stainless steel orifice
- Calibrated against standard oils referenced to certified NIST oils (National Institute of Standards and Technology of United States)
- Certified cups available on request
DIN Flow Cup
This cup holds 100 ml ± 1 ml, and has an integrated orifice with a diameter of 4 mm ± 0.02 mm.
- For low viscosity liquids
- Body made of anodized aluminum
- Stainless steel orifice, interior polished
- Calibrated against standard oils referenced to certified PTB oils (Federal Institute of Physics and Metrology of Germany) to be within 3% (drain time of calibration oil)
ISO Flow Cup
This cup has a longer orifice, less tapered body and slightly different inner dimensions than the DIN 53211* flow cup and thus provides different efflux times. The extended measurement range makes the ISO cup a useful supplement of the DIN cup.
- Recommended for international use
- Body made of anodized aluminum
- Stainless steel orifice, interior polished
- Calibrated against standard oils referenced to certified PTB oils to be within 3% (drain time of calibration oil)
Ford Cup No. 4
DIN Cup 4 Certificate included
Flow Cup ISO 3 mm
Certificate included
For Standard oils
see page 262.
Centistokes = K * efflux time - (C/ efflux time)
Centipose = Centistokes x Specific Gravity
For Certification Services
see page 269.
| Standards |
| ASTM | D 5125 | |
| ISO | 2431 | |
| Standards |
| DIN | 53 211* | |
| Standards |
| ASTM | D 333, D 365, D 1200 |
|
| K | C | |||
| DIN 4 mm | 4.57 | 452 | ||
| K | C | |||
| Ford Cup No. 2 | 1.24 | 770 | ||
| Ford Cup No. 3 | 2.31 | 550 | ||
| Ford Cup No.4 | 3.7 | 400 | ||
| K | C | |||
| ISO 3 mm | 0.443 | 200 | ||
| ISO 4 mm | 1.37 | 200 | ||
| ISO 5 mm | 3.28 | 220 | ||
| ISO 6 mm | 6.9 | 570 | ||
** One orifice size must be selected (PV-0152 through PV-0158) on the following page prior to placing an order.
Flow Cups
* DIN 53211 was withdrawn in October 1996
| Ordering Information | Technical Specifications |
Glass Plate
Ford Stand with Waterbath
Temperature
Control
Jacket
Thermometer
Stand for
Flow Cup
Flow Cups
Recommended Accessories
Glass
Plate
Ring
Stand
with Cup
Thermometer
| Ordering Information | Accessories |